Data sent by current transformers are processed by protection, control and monitoring units. The ct ratio is the ratio of primary current input to secondary current output at full load. The components required to monitor an ngr are an se330, a 20 or 100k. Instrument transformers convert signal levels from dangerous high voltage or inconvenient high current, or current at high voltage to levels appropriate for metering. A general overview of abbs current and voltage transformers. Portable ct pt analyzertransformer testgfuve electronics. Measure or detecting leakage current singlephase or threephase with or without neutral applications. Fiberoptic current and voltage sensors for highvoltage. The current transformer is designed to connect in series with the line to transform the line current to the standard 5 amperes suitable for the.
When the circuit burden gets too large, the ct secondary voltage becomes distorted. Ctms series current transformers produce an output of current in proportion to the monitored circuit current. A range of 3in1 current transformers combine three traditional current transformers in one moulded case. Equivalent current transformer circuit x 1 primary leakage reactance r 1 primary winding resistance x 2 secondary leakage reactance z 0 magnetizing impedance r 2 secondary winding resistance z b secondary load note. Automatic calculation of excitation knee point value. Erseries sensing resistor, and a current transformer ct. Gflzz075735q epoxy resin medium voltage outdoor current transformer.
As long as the current to be measured are small and at low voltage, the direct method of connecting the instruments and relays in the circuits is convenient and adequate. Current transformers 100 3511 charter park drive san jose, ca 956 800. Powercircuit elements other than neutral connected ngrs that purposefully connect the power system to ground are often. Cbt94f core balanced current transformers crompton instruments. On subtractive polarity transformers the h1 primary lead and the x1 secondary lead will be on the same. This transformer has a 500 a1 a current ratio and a rated output load of 1 va, which corresponds to a nominal burden of 1. The current transformer function is different than that of a voltage transformer. Magnelab sct1250200 split core current transformer ct. At that time, ref relay shows 4 kv neutral voltage. If the currents exceeding several hundreds of amperes have to circulate continuously through the. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load. Why do current transformers have a minimum frequency. Select the model with a range that is equal to or slightly higher than the normal operating amperage. Withstand test of power frequency alternating current.
Normally the current transformer has a burden resistor of 1 to 100 ohms and this totally swamps the magnetization impedance. S48897 neutral current transformer, unrated schneider. If a ct test switch is used, the switch must have a makebeforebreak contact pattern to. Operating a current transformer as a voltage transformer provides a costeffective alternative to injection transformers sold as test accessories see pdf. Transformer is equipped with one core and coil assembly rated for measurement and protection. Neutral current 173% of line neutral current 171% of line neutral current 153% of line table 1. Traditional, often line frequency current transformers, hall effect current transformers and switchmode power supply smps current transformers are examined in depth. This ct ps class out put is using for ref restricted earth fault protection of transformer windingie. The wave shape of the output is nearly identical to the monitored circuit wave shape. With respect to ansi cts, some of the major details that one would look for in the ct are. Pdf addressing localized saturation of generator neutral current. Polarity refers to the instantaneous direction of the primary current with respect to the secondary current and is determined by the way the transformer leads are brought out of the case. Current transformer free download as powerpoint presentation. Due to this, it can easily recover from dc magnetization, even with a low ac measured current.
Current transformer accuracy is specified by the standards ieee std c57. For instance, if i put 10 ma 50hz through a conductor passing through the sensor as100 1. Normally the leakage fluxes x 1 and x 2 can be neglected. Within electrical systems, current transformers are essential to ensure the correct functioning and control of equipment and for providing.
A current transformer operates with a set primary current and will try to output a constant current to the load, independent of the load. Other harmonics, including triplens such as 9th, 15th, etc. Instrument transformers mitsubishi electric corporation. Aftab khan abb inc, 100 distribution circle, mount pleasant, pa 15666, usa abstract. Current measurement to 0 800a, seven models ct 0200.
Current transformers are available at mouser electronics. Third harmonic in single phase nonlinear load current is the major contributor to neutral current. What is neutral current transformer and where do we use it. On the transmission route of electrical energy between generator and consumer, the exact detection of currents is required at a large number of measuring points.
In the interest of small size and widest bandwidth, the smallest practical size of cores is used. The current transformer will operate into either a short circuit or a resistive load until the voltage induced is enough to. A current transformer ct is an instrument transformer in which the secondary current is substantially proportional to primary current and differs in phase from it by ideally zero degree ct accuracy class or current transformer class. Current transformer ct5mrn series expand input range for use with meter relays 5060 hz, 1. The leakage current is determined by passing the phase conductors. Gfm25ct neutral current transformer schneider electric. Datasheet of as100 mentions a maximum current it can sense before saturation, but what is the minimum current it can sense.
A current transformer is similar to a electrical power transformer to some extent, but there are some difference in construction and. Current transformers can be used to supply information for measuring power flows and the electrical inputs for the operation of protective relays associated with the transmission and distribution circuits or for power transformers. Current transformer design tool assists design engineers in choosing the most appropriate core material and size for a number of current transformer ct topologies. Fiberoptic current and voltage sensors for highvoltage substations k. This behavior is used to calculate the value of the burden resistor for an optimum currenttovoltage relationship. Neutral current remains the same for the load range of 5 85 mw. Primary current is always defined by the external circuit thats good because now we dont need to worry about saturation or the current getting bigger at lower frequencies. When insertion loss specifications must be met with greater rf power or dc current applied, this must be taken into account in the transformer design to prevent saturation of the magnetic.
This is where current transformers come into play, the quality of which decisively determines the quality of the measured data. The basics of current transformers nk technologies. Addressing localized saturation of generator neutral current transformers. A current transformer is defined as as an instrument transformer in which the secondary current is substantially proportional to the primary current under normal conditions of operation and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections. High current, high accuracy, high output voltage aq series. As a result, the subcommittee indicated that there was not enough evidence to require neutral conductors to be oversized by any typical factor. Neutral current transformer is connecting between the neutral of transformer and earth. If the primary current changes the secondary current output will change accordingly. Flexcore manufactures and warehouses a large selection of current transformers, transducers, meters and more for measurement, monitoring, and control of current, power, and energy applications.
Courtesy siemens current transformers cts are used to convert highlevel currents to a smaller more reasonable level for use as inputs to protection relays and metering equipment. Splitphase phaseto neutral loads such as 120v residential outlets require a single ct singlephase phasetophase loads such as 240v residential hot water heater require 2 cts. Chart 1 neutral current with k4 transformer the per unit harmonic current for the various harmonics are. Current transformer design guide an effective design of a ring type c. High voltage sf6 current transformers image source. The supportingtype current instrument transformers gflzz075735q are fully enclosed and cast in epoxy resin. If the measured load is purely single phase no current on the neutral such as many residential solar inverters, a single ct can be used.